歯科教育
オンライン歯科教育 歯科教育のための講義とビデオ オンラインデンタルCE 歯科教育のための論文 熟練した歯科教育者 歯科製品教育 デンタルフォーラム
 

About the Company

    

BIOMET 3i offers one of implant dentistry’s most comprehensive lines of implants and abutments, augmented by a growing line of site preparation and regenerative products. BIOMET 3i pioneered the development of biologically driven implants, winning worldwide acclaim for the microtextured surface and superior clinical success rates of the OSSEOTITE® Implant.

Headquartered in Palm Beach Gardens, Florida, with operations throughout the world, BIOMET 3i is one of the leading companies in the oral reconstruction market. Of equal importance, BIOMET 3i brings the same innovation, high standards and comprehensive approach to customer service, practice and laboratory support and education.


The BIOMET 3i Value Proposition:
  • Quality-Driven Capabilities
  • Practical Innovation
  • Evidence-Based Research
  • Clinician-Driven Service
  • Practice-Oriented Relationship
Managing the Extraction Site - Optimal Preservation and Enhancement Techniques
Presented by Michael Sonick, DMD
There is rarely a day that clinicians do not have to deal with an extraction site. If implant therapy is a consideration, then bone and soft tissue quantity and quality must be factored into treatment options. The ideal opportunity for bone preservation exists at the time of tooth extraction. All too often this opportunity is lost. Extraction techniques will be demonstrated that not only preserve but augment the amount of alveolar bone. The importance of piezosurgery, atraumatic surgical technique, the use of bone grafts, resorbable membranes and growth factors will be elucidated along with soft tissue enhancement.
Implants and Interdisciplinary Treatment Planning for Optimum Outcome Results - The Team Approach - Part 1 of 2
Presented by Rhonda Mullins
This course will help you consistently achieve a systematic approach to treatment planning and getting a "yes", from your customers with the development of your Interdisciplinary Teams. Getting patients to "buy" verses "sell" is one of the vital keys you will take-away. This course will increase your capacity to design, choose and develop a "Top Line" team internally and externally (Collaborative Clinicians). Attendees will learn how connectivity and communication are vital "close the cracks" tools for enrollment and the establishment of Interdisciplinary Teams when assessing, cultivating, recommending and delivering more comprehensive care driven cases that transform, add value and benefit your customers with "Optimum Outcome Results".

Surface Technologies

The NanoTite™ Implant
The NanoTite Implant represents BIOMET 3i’s most recent advanced dental implant surface technology since the introduction of the OSSEOTITE® Implant in 1996. The NanoTite Implant is the patented OSSEOTITE Dual-acid etched Surface, which is then further treated with a deposition of nanometer scale crystals of calcium phosphate. This is known as the Discrete Crystalline Deposition Process or DCD™ Process. The surface treatment is a discrete crystalline deposition on the OSSEOTITE Surface, not a plasma sprayed coating.

The synergistic effect of these two technologies, the OSSEOTITE Surface and DCD Process, has demonstrated promising results in animal studies. It is also the present focus of numerous prospective human research projects. Because of this synergistic effect, a more complex microsurface is created. Preclinical studies demonstrated that the NanoTite Surface treatment, when compared to OSSEOTITE Control Implants, significantly improves the rate and extent of bone to implant contact and results in statistically significant enhanced integration.

Please wait while the player is loaded.

Surgical And Site Preparation Technologies

Certain PREVAIL® Platform Switching Implants
Certain® PREVAIL® Implant
Certain Tapered PREVAIL® Implant

Tapered Implants
Certain Internal Connection Tapered Implants
Tapered External Connection Implants

Parallel Walled Implants
Certain Internal Connection Implants
External Connection Implants

The Navigator™ System For CT Guided Surgery
Navigator Surgical Kit
Navigator Laboratory Kit

OsseoGuard™ Resorbable Collagen Membrane

RegenerOss Family Of Products
Endobon® Xenograft Granules
RegenerOss Allograft Putty
RegenerOss Allograft

Restorative Technologies

Cement-Retained Restorations
Provide Abutments
GingiHue® Posts
ZiReal® Posts

Screw-Retained Restorations
UCLA Abutments
IOL® Abutments
Conical Abutments

OverdentSURE Restorations
DIEM® IOL Abutments
Standard Abutments
LOCATOR® Abutments

Provisional Restorations
PreFormance® Posts
PreFormance Temporary Cylinders

Please wait while the player is loaded.

Please Note: Not all products are available outside the U.S. Please contact your local BIOMET 3i Sales Representative for availability.

お取扱い製品

[詳細を表示する]
製品詳細:

Osseointegration, primary stability and restorative flexibility align in an inspiring design – the addition of the PREVAIL Platform Switching™ Feature to the NanoTite Tapered Implant is designed to help clinicians pursue the preservation of crestal bone and soft tissue1,2, allowing for optimal aesthetic outcomes.

The NanoTite Tapered PREVAIL Implant Features:
  • The NanoTite Surface - A Bone Bonding® Surface*3,4 in which preclinical studies demonstrated an improved rate and extent of osseointegration† due to the Discrete Crystalline Deposition™ (DCD™) of nano-scale calcium phosphate

  • Innovative Tapered Design - Thread angle, depth and pitch produce an anchoring “bite in bone” response, establishing primary stability

  • Built-In Platform Switching - Moving the Implant Abutment Junction (IAJ) in from the implant shoulder limits the reformation of biologic width and allows for crestal bone preservation around the implant



お問合せ先
Customer Service
電話: 800.342.5454
メールアドレス: 3ics@3implant.com

郵送先住所
4555 Riverside Drive
Palm Beach Gardens, FL 33410

BIOMET 3i Website
お問合せ | Privacy Policy | Terms of Use
©2012

English
お問合せ · ログイン · 登録